Flexibility to Address a Variety of AC Power Control Requirements, Locally or Remotely Use it Anywhere in The World
Low Price point, | ||||||
|
| ||||||
|
WHAT IS IT?
The U-X3 supports input AC voltages from 110V to 250V and has a 15 Amp circuit breaker.
It uses internationally standard IEC320 AC connectors. This combination allows it to
be used anywhere in the world with locally available power cords. Various AC power
cords as well as a Universal Adapter that provides connections for any type of AC
Plug in the world are also optionally available.
The U-X3 provides a number of methods to control it, allowing it to be used locally
or remotely for a number of different applications; from simply resetting
DSL modem/routers to automatically resetting kiosks or other equipment that may hang
from time to time. Or even to turn the power ON or OFF on certain equipment for protection,
security or simply to add a little green to the environment.
THE HARDWARE
The front panel supports three multi-function connectors. A USB connector and two
RJ-11 connectors, any of which can be used to configure the unit or to send the
ON/OFF/RESET power control commands, depending on the application. The RJ-11s provide
the connection for a standard telephone line for remote control. They are also used for
the RS-232 and Upstream Downstream connections as well as to connect other external CPS
controllers or Base Units.
SETUP PREFERENCES
Example:
HOW IT CAN BE CONTROLLED?
Remote Control over a standard telephone line is provided through the Ring
Count RESET feature (standard). This feature simply counts the rings and RESETS once the
ring threshold is reached.
Our new (optional) Internal Touch Tone Option (ITTO) is also available. It
provides a multi-level password and allows the ON/OFF/RESET commands as well as inquires to
be sent using a touch tone key pad. It can also share the line with other devices (phone, fax,
TAD, but no inbound modem) and allows some of the set up preferences to be changed remotely as zwell.
The commands may also be appended to a modem's AT dial string for more automated entry, even
though there is no modem at the U-X3 end. Multiple ITTOs/U-X3s with different passwords may also
be connected to the same phone line.
External Remote Controllers are also available to provide additional methods of
remote access.
Automatic control
Auto Ping is used to RESET network equipment
(modems, routers, gateways, firewalls etc.). It pings outside addresses through the target devices and
RESETS them if the return pings are not detected. You can assign two IP addresses for up to 30 AC jacks.
Heartbeat is used to monitor the server,
connected to the USB or RS-232 serial port on the U-X3. It will RESET one AC JACK on the U-X3
if serial transmission from the server is not detected within a prescribed time. A DLL is also
available to help incorporate the heartbeat into your application if required.
Serial Net allows the serial Control Commands to be sent
to the remote location "Control PC/server" over a TCP/IP network.
FLEXIBILITY Wow!
Or use the External IP Controller (N-RRC) as your primary method of AC power control, but
when the network equipment is down, you can rely on the Auto Ping to automatically reset it
or use any of the "out of band" touch-tone option or Ring count RESET feature to reset the
Router modem etc.
Of course all of this can be changed along with a number of other operating parameters through
the USB port on the U-X3. It is truly a remarkable device. Its flexibility allows it to be
used for a variety of power control requirements. It will keep your blood pressure in check
and miles off of you car.
AC Power Command Examples
A typical serial port command to RESET POWER on Box #2, Port #1 is *213
If this were sent as a touch-tone command through an External Telephone Line Controller, it would
be preceded with the controller #, Password (up to six numbers), and the Port number of the Controller
(multi-port units) that the Power Strip is attached to:
This could also be sent from a modem by appending it to the AT dial string. Even though there
may not be a modem at the Power Strip end.
Wild card and Global Commands are also available. *PON This "global Command" will turn ON all of the ports on all of the boxes according to the delays applied in the setupTo send this command via Touch-Tones to the Internal Controller (ITTO) enter The manual ON/OFF switch can also be used to power the CPS ON or OFF. It will power ON according to the preferences that you selected.
SPECIFICATIONS - PRICE Automatic Power Cycle (APC)
Item No SWTUX3-CP Price $149.00
Physical 6.25" W x 4.25" D x 2.25" H, 1 lbs.
Connectors (2) RJ-11 TelCo/Control,
(1) USB,
(4) AC Receptacles (IN/OUT)
LEDs (5) Port, Power, TX/RX
Switches (1) On/Off 15 Amp breaker
Bell (1) Audible Response
Cable (1) 7' RJ-11 Phone Cable
Adaptor None
AC Power 115V/50-60Hz, 15 Amps to
220V/50Hz, 10 Amps
---------- OPTIONAL ADAPTERS ------------
RJ FILTERED ADAPTER (9 PIN to RJ-11) Item No CA9R11-IPN-F Price $18.00 (Required for Serial Port Connection)------------ POWER CORDS ----------------
OPTIONAL AC POWER CORDS and ADAPTERS
IN AC Adapter Cords - FROM POWER MAIN TO THE IPC (Country Connector to IEC 320-14) A - North American 110-115V 6 foot (NEMA 5-15 Receptacle to IEC C13) Item No NA-IPC Price $2.25 A - European 6 feet two prong Item No E2-IPC Price $6.20 OUT AC Adapter Cords - FROM IPC to the EQUIPMENT B - PC Extension 6 foot (IEC 320-C13 to IEC 320-C14) Item No IPC-PCX Price $3.20 C - North American 1 foot (IEC 320-C13 to Equipment, PC, Power Strip, etc.) Item No IPC-NA Price $1.70 D - Universal Adapter (Connects to the IPC OUT and accepts any country AC connector) Item No IPC-UV Price $7.50 For more Help with Power Cords - Click Here---------- REMOTE CONTROLLERS -----------
Optional Internal Touch Tone Controller
Item No ITTOARRC Price $ 29.00
Optional External Controllers
External TELEPHONE LINE Controllers
SP-RRC One Telco Line and One Control Port (to U-X3)
Item No SWTSPRRC Price $135.00
3P-RRC One Telco Line and Three Control Ports (to U-X3)
Item No SWT3PRRC Price $195.00
FTS One Telco Line and Three Control Ports (to U-X3)
Item No SWTFTS Price $225.00
FTS-8 One Telco Line and Eight Control Ports (to U-X3)
Item No SWTFTS8 Price $395.00
NETWORK Controller
N-RRC One RJ-45 TCP/IP Network Connection and One Control Port (to U-X3)
Item No SWTRRC-N Price $169.00
Cell Controller
C-RC One RS-232 port and one Control Port (to U-X3)
Item No SWTCRC Price $425.00
See the specific Controller for additional specifications
| ||||||
|