3P-RRC

THREE PORT REMOTE REBOOT CONTROLLER (3P-RRC)

Selection and remote control of up to 3 ports (AC power or reset button reboots) over a single dial line.

$195.00

Qty:


SAMPLE BASE UNITS
ARR Picture   

Intelligent AC
Power Strip

ARR Picture

PC-RJ Cable
Interface Assembly



  • AC Power or Reset Button Reboots

  • Remote Maintenance Applications

  • AC Power On/Off Control Too

  • Remote Programming

  • Touch-Tone Password Up To Six Digits

  • Touch-Tone Control Commands

  • Very Easy To Use

  • Cable Distances Up To 2000' or Rack Mount



Introduction
The THREE PORT REMOTE REBOOT CONTROLLER (3P-RRC) is an out-of-band (dial-line) reset controller that is primarily used to selectively reset equipment connected to each of its three Control Ports through a series of Touch-Tone commands.

The 3P-RRC can be installed on any analog dial-line and can share the line with other normal voice, modem, fax or PBX requirements. The shared Default Port can support the phone equipment and a Reset device simultaneously, if required.

It can also be used as a security device by simply using it to turn the remote equipment, such as a modem, ON or OFF.

Note that the 3P-RRC is a controller only. It has three RJ-11 ports and requires a CPS Base Unit (such as an Intelligent AC Power Strip or an RJ-Cable Assembly) on each port that you wish to control. They are connected to the 3P-RRC via an RJ-11 connector. They can be physically located locally or up to 2000' from the controller, using standard phone or LAN cable.

The Intelligent AC Power Strip is normally used when the target machine does not have a reset button or when direct power ON/OFF control is also required. It has six AC outlets: two (2x4), four (4x2), or all six (6x0) may be designated as "Controlled Outlets" at the time of the order. The others may be used as normal surge protected AC outlets for printers, monitors or other equipment that do not require resets or On/Off control.

The RJ-Cable Assembly allows the 3P-RRC to perform a push-button reset (soft reset) on a PC. To use it, the target machine must have a Reset button that connects to the motherboard. It installs in a vacant I/O opening on the back of the machine's case, but does not require a slot on the motherboard. The connecting cables allow the Reset button to also be used normally.

ATX Motherboards
The BIOS on ATX motherboards normally has several options to deal with the loss of AC power: to power-up only after the momentary Power Button is pressed (default), to return to its previous state before the AC power was lost, or to power-up when the AC power is restored. This last option allows the systems to be used with the Intelligent AC Power Strip for direct AC power control.

However, these motherboards can also be used with the Auto Push Board(APB). The APB performs the first option above by pushing the Power Button once AC power returns. (See Resetting ATX Motherboards.)

How to control it
The programmable administrator's touch-tone Configuration Commands and the caller's Access Codes and Control Commands can be entered from any touch-tone telephone pad. They may also be appended to the AT dial command string of a dial modem. The 3P-RRC will accept the commands remotely through its Telephone Line Port "TelCo" or the local default Phone Port or both. This provides remote dial control or local control over the building wiring or both. The commands are stored in EEPROM in the event of a power failure.

A typical touch-tone command may be:
(phone #) (access code & port #) (on/off/reset)

How it works
When a call is received, the 3P-RRC either answers the call immediately or passes the rings through to the default port allowing something else to answer first. In either event it listens for a Command to begin for xx time and takes the appropriate action if it hears it. If a Command is not heard, the call may be aborted (Secure Mode) or passed to the Default Port (Shared Mode).


One Port & Eight Port models are also available.


THREE PORT REMOTE REBOOT CONTROLLER (3P-RRC)
Item No SWT3PRRC Price $195.00

Also Available
Item No SWTSPRRC (1 Port) Price $135.00
Item No SWTMPRRC (8 Ports) Price $325.00

Physical 4.5" W x 3" D x 1.25" H, 1 lb.
Connectors (4) RJ-11 TelCo, Reset Control
LEDs (5) Power, Mode
Switches (1) 4-Bit Dip, (1) Pushbutton
Bell None
Cable (1) 5' RJ-11 Phone Cable
Adaptor None
AC Power Wall Mount 9VAC 1A, 115V/60Hz

NOTE: For 220V/50Hz, add (-INT) to the Item No


------ NON-ADDRESSABLE BASE UNITS ------

OPTIONAL INTELLIGENT AC POWER STRIP
2 Controlled and 4 "Normal" Outlets
Item No SWTAC6-A2-2x4 Price $ 79.00

4 Controlled and 2 "Normal" Outlets
Item No SWTAC6-A2-4x2 Price $ 79.00

6 Controlled Outlets
Item No SWTAC6-A2-6x0 Price $ 79.00

Physical 12" W x 2.5" D x 1.5" H, 2 lbs.
Connectors (2) RJ-11 TelCo/Control,
(6) AC Receptacles
LEDs (1) Surge Protection
Switches (1) Main Toggle On/Off
Bell None
Cable (1) 5' RJ-11 Phone Cable
Adaptor None
AC Power 115V/60Hz, 15 Amps

NOTE: For 220V/50Hz, see the IPC.


OPTIONAL INTERNATIONAL POWER CONTROLLER (IPC)
See the IPC


OPTIONAL PC-RJ CABLE INTERFACE ASSEMBLY
Item No CAPC2-RJ Price $ 15.00

Physical 5.5" W x 2.5" D x .75" H, .25 lbs.
Connectors (1) RJ-11 Interface,
(4) PC Headers Pins
LEDs None
Switches None
Bell None
Cable (1) 2' M/F Reset Switch Cable,
(1) 2' F/F Motherboard Reset Cable,
(1) 5' RJ-11 Cable
Adaptor None
AC Power None


OPTIONAL RELAY BOX
See the Relay Box


-------- ADDRESSABLE BASE UNITS --------

OPTIONAL A/B, MATRIX or X2 SWITCH
See the AB-M


OPTIONAL INTELLIGENT AUTO PUSH BOARD (I-APB)
See the APB


OPTIONAL INTELLIGENT POWER NODE (IPN)
See the IPN